The instrumentÆs built-in display and setpoint control eliminate the need for separate power supply and readout electronics, that can cost as much as the flow controller. A straight, large diameter sensor tube prevents clogging and contamination, and the fast response valve provides precise one-step control of critical gas flows. You simply set it and forget it!
FMA-1900 provides both digital readout of mass flow rate and setpoint adjustment on-board! Available in your choice of engineering units at flow rates of up to 50 standard liters per minute (SLPM), the unit provides a continuous display of actual gas mass flow rate. To change flow rates, you simply adjust the reading on the display. For applications that require remote setpoint control, the unit accepts 0-5 VDC or 4-20 mA command signals. FMA-1900 flow controller is powered by a regulated 15 or 24 VDC power source, normally provided by the convenient OMEGA Power-Pak, or optionally by the customer. Power and setpoint control are supplied through a 15-pin ôDö connector. Both 0-5 VDC and 4-20 mA output signals are available for data-management and control purposes.
Range Table | |||
Code | SCCM | Code | SLM |
02 | 0-10 | 14 | 0-1 |
04 | 0-20 | 16 | 0-2 |
06 | 0-50 | 18 | 0-5 |
08 | 0-100 | 20 | 0-10 |
10 | 0-200 | 24 | 0-20 |
12 | 0-500 | 26 | 0-30 |
27 | 0-40 | ||
28 | 0-50 |
To Order (Specify Model Number) | ||
Model No. | Price | Description |
FMA19(*)-(**) | $954+ | Mass flow controller with display and control valve |
Comes with complete operatorÆs manual. *Insert range code, from table to complete the model numbers in the chart above. ** Flow ranges specified are for nitrogen or air at 30 psig. When used for other gases, a multiplication factor is used to determine the flowrate, and the digital display must be rescaled in the field. Or request "Special Calibration: for____ gas at ____ (temperature) and _____ (pressure) inlet _____ (pressure) outlet. †For range code 02 add $120 to price. For 4-20 mA output add suffix "-I" to model number, No extra Charge. Ordering Example: FMA1912-(N2, 70°F, 30 psi, 0 psi) mass flow controller calibrated for nitrogen at 30 psi inlet, 0 psi outlet, 70░F temperature range from 0-500 SCCM, $795. |
Model No. | Price | Description | ||
FMA198PW | $60 | Plug in 24 Vdc @ 250 mA power supply 115 Vac - 50 Hz with 15 pin D connector and 3 feet cable | ||
FMA198PW-220 | 60 | Plug in 24 Vdc @ 250 mA power supply 220 Vac - 50 Hz with 15 pin D connector and 3 feet cable |
|
|